Melco EMT 10T Specifications Page 95

  • Download
  • Add to my manuals
  • Print
  • Page
    / 128
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 94
3. Slide the picker assembly out of the picker bracket mount.
When re-attaching the picker link to the picker assembly, refer to the alignment
section of this chapter for the alignment procedure for the picker position.
Movable Knife
1. Remove the screws holding the needle plate. Remove the needle plate.
2. Remove the screws holding the front and rear bed covers and remove the covers.
3. Lift the forward end of the connecting link from the pin on the movable knife
drive arm (see Figure 4-5).
4. Push the movable knife all the way back until it stops.
5. By rotating counter clockwise, loosen the hex head screw holding the movable
knife to the top of the knife drive arm.
6. Rotate the movable knife out of the adjustable fixed knife, then remove the hex
head screw and the movable knife.
7. Place the new movable knife on the top of the knife drive arm, positioning the
alignment hole in the knife over the alignment pin in the arm.
8. Apply Loctite 222 screw adhesive (or equivalent) and install the hex head screw
and snug it with your fingers.
mounting
screws
Picker
Bracket
Mount
Picker
Picker Link
Swivel Pivot
set screw
External
Retaining
Ring
Picker
Base and
shaft
Figure 4 - 4
Movable Knife 4 - 7
110291-01, Rev D 4. Trimmer Maintenance
Page view 94
1 2 ... 90 91 92 93 94 95 96 97 98 99 100 ... 127 128

Comments to this Manuals

No comments